AC Drive Hitachi X200 Series Inverter
The Hitachi X200 AC Drive Frequency Inverter has been designed with the OEM in mind. Offering an amazing array of features to help keep the cost of both the Inverter and the machine itself down.
- Power: 1.5kW
- Amps: 3.8
- Supply: Three Phase 400v
- Model: X200-015HFEF
- Filter: Built-In
- Performance: Basic
- Dimensions: 0 0 0
- Weight: 5 kg
- Torque: Constant Torque General Purpose
Type: Hitachi X200 General Purpose compact senseless vector AC Drive frequency inverter
The Hitachi X200 economic AC drive solution for applications up to 7.5 kW. Hitachi X200 frequency inverters are suitable for pump and fan applications as well as for common tasks in machine construction. The standard "Safe Stop" function according to EN954-1 class 3 provides additional functionality and cost effectiveness by allowing the removal of the isolating contactor. The Safety Relay is still needed but the safety relay can now input to the Hitachi X200AC Drive directly to isolate the motor. With the integrated EMC filter the inverter fulfils EN61800-3 standard and is complying with standards like CE, UL, cUL, c-Tick and RoHS.
Environment-friendly Inverter
RoHS compliance for all models
Integrated EMC Filter
Cost and space reduction compared with external EMC filter. (European version only)
- Single-phase input: EN61800-3 cat.C1
- Three-phase input: EN61800-3 cat.C2
Emergency Stop Function
Shut off INV output by hardware without software (CPU) high quality emergency stop
Improved Trip Avoidance Function
Over current and over voltage suppressing function is incorporated. This function reduces inverter tripping. The X200 decelerates and stops the motor using regenerative energy from the motor even though the power is not supplied.
Non-stop operation at IPF
This can achieve smooth retry even when the IPF (Instantaneous Power Failure) occurs. This is useful especially in Fan and Pump application
Automatic Energy-saving Function
The X200 delivers "real-time" energy-saving operation for your fan and pump applications. This function insure that motor operates at minimum current in response to the torque required by the load.
Micro Surge Voltage suppress function (Patent registered in Japan, USA & Korea)
Hitachi original PWM control suppressing Motor terminal Voltage less than 2 times of INV DC voltage E. Lower than Hitachi motor Max. insulation voltage (1.250V)
(during regeneration operation increase the DC bus voltage may over motor max.insulation voltage)
Network Compatibility
RS-485 is provided as standard for Modbus-RTU serial communication PROFIBUS. CAN open option modules are available soon.
Side-by-side installation
Since an inverter can be stuck and installed in a horizontal direction, a space can be used effectively.
Versatile Functions
- Pure analogue monitor output (10-bit, 0-10VDC)
- Low load detection
- External thermistor terminal (PTC)
- Cooling-fan on/off
- Instantaneous power failure recovery
- Second motor setting
- 3-wire control
- Analogue input selection
- Second acceleration/deceleration setting
- Jogging
- Auto-carrier frequency reduction
- Unattended start protection (USP)
- Analogue input wire-break detection